36
Note: For 5V TTL encoders, a 5V supply is available on second interface,
X3B terminal 7.
If an incremental encoder does not have N+/N- tracks then the
corresponding inputs on the encoder interface card must be
jumpered high/low or the drive will trigger the error, E.ENC1. For
example, connect N+ (X3A.5 ) to 5V (X3B.7) and N- (X3A.6) to 0V
(X3A.8).
3.2.2 X3A TTL Inc. Enc.
In Screw Terminals
Connect the incremental encoder mounted on the motor to the 8 position
terminal connector at X3A. This connection provides speed feedback
and is imperative to the proper operation of the F5M.
ONLY when the inverter is switched off and the voltage
supply is disconnected may the feedback connectors
be removed or connected!
The following speci cations apply to encoder interface X3A, channel 1
Max. operating frequency: 300 kHz.
Maximum cable length: 50m (164 ft) (RS422)
Internal terminating resistance: R
t
= 120
RS422 or TTL level square wave
voltage level: 2...5 Vdc
X3A
Channel 1
X3B
Channel 2
X3A
Channel 1
X3B
Channel 2
Pos Signal Description
1 A+ TTL incremental encoder track A
2 A- Differential signal to A+
3 B+ TTL incremental encoder track B
4 B- Differential signal to B+
5 N+ TTL Zero track
6 N- Difference signal to N+
7 15/24 V Voltage output 15/20...30 V, power supply for the encoder,
switchable with dip switch S100
8 COM 0V reference for voltage supply
- GND connect the outer cable shield to an earth ground con-
nection on the elevator drive .
Plug in screw
terminal X3A
1 2345678
Installation and Connection
i

Table of Contents

Other manuals for KEB COMBIVERT F5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 and is the answer not in the manual?

KEB COMBIVERT F5 Specifications

General IconGeneral
CategoryDC Drives
Enclosure RatingIP20
Control ModeVector Control, V/f Control
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Fieldbus CommunicationPROFIBUS, CANopen
Communication InterfacesRS-485
Input Voltage380-480V AC
Cooling MethodForced air cooling (fan)