EasyManuals Logo

Keithley 2002 Getting Started Manual

Keithley 2002
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
Index
A
Accessories 4-8
Accuracy 4-2
Amps fuse 1-7
Annunciators 1-4
Auto filter 2-16
B
Bench default 1-9, 2-13
Buffer 3-23, 3-24
Buffer (Data Store) 2-18
Burst mode 2-19
C
Cables 4-9
Channels 2-23, 2-24, 2-27, 3-15, 3-26, 3-28
Command syntax 3-10
Common commands 3-5
Configuration settings 2-7
CONFIGure menus 2-6
Control source 2-12
Counters 2-13
Current measurements 1-11
D
Data store (Buffer) 3-15
Delta 2-25
Device action 2-13
Digital I/O 1-7
Display 1-8
Display keys 1-5, 2-2
E
External scanning 2-26
F
Fan 1-7
Filter 2-16
Filter modes 2-16
Filter types 2-16
Frequency measurements 1-14
Fresh readings 3-12
Front panel 1-4
Function keys 1-4
I
Idle 2-11
IEEE-488 3-18
IEEE-488 bus 3-3
IEEE-488 connector 1-7
IEEE-488.2 3-3
Input connections 1-5, 1-7
Inputs 1-5
Internal scanning 2-22
L
Line fuse 1-7
Long form 3-8
M
Main menu 2-6
Manuals 4-9
Math 2-20
Measurement ranges 1-2
Menus 2-6, 2-8
Model 1801 Nanovolt Preamp 1-3
Model 2001-SCAN 1-16, 2-22, 3-26
Model 2001-SCAN Scanner Card 1-3
Model 2001-TCSCAN 1-16, 2-22
Model 2001-TCSCAN Thermocouple Scanner
Card 1-3
Model 7001 or 7002 Switch System 2-26
Models 7007-1 and 7007-2 3-3
Multiple displays 2-2
O
Operation keys 1-5
Option card 1-3
Option slot 1-7
Output trigger 2-13
P
Percent 2-20
Percent deviation 2-20
Polynomial 2-20
Power line input 1-7
Power-up 1-8
Primary address 3-4
Product overview 1-2
Program examples 3-18
Probes 4-8, 4-9
Q
Query commands 3-9
R
Range keys 1-4
Ratio 2-25
Rear panel 1-6
Relative 2-10
Resistance measurements 1-12
Resolution 2-15
RTDs 1-16
S
Scanner card 1-16
Scanning 2-22, 2-26
SCPI 3-3, 3-6
SCPI command syntax 3-7

Other manuals for Keithley 2002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2002 and is the answer not in the manual?

Keithley 2002 Specifications

General IconGeneral
Resolution8.5 digits
DC Voltage Accuracy±0.0006%
Maximum DC Voltage1000 V
Maximum AC Voltage750 V
Maximum DC Current3 A
Maximum AC Current3 A
ConnectivityGPIB, RS-232
DC Voltage Range100 mV to 1000 V
AC Voltage Range100 mV to 750 V
Resistance Range10 Ω to 1 GΩ
Model2002
CategoryMultimeter
InterfaceGPIB, RS-232
AC Current Accuracy±0.1%
Frequency Range0.1Hz to 300kHz
DisplayVFD
TypeDigital
Power Supply100-240V AC, 50/60Hz
Current Range (DC)100 μA to 3 A
Current Accuracy (DC)±0.01%
Current Range (AC)100 μA to 3 A
Current Accuracy (AC)±0.1%
DC Current Range100 μA to 3 A
AC Current Range100 μA to 3 A