Series 3700A System Switch/Multimeter Reference Manual Section 9: Introduction to TSP operation
3700AS-901-01 Rev. D/June 2018 9-31
Reading buffer
Reading buffers capture measurements, ranges, instrument status, and output states of the
instrument.
bufferVar.appendmode (on page 11-16)
bufferVar.basetimefractional (on page 11-17)
bufferVar.basetimeseconds (on page 11-18)
bufferVar.cachemode (on page 11-19)
bufferVar.capacity (on page 11-19)
bufferVar.channels (on page 11-20)
bufferVar.clear() (on page 11-21)
bufferVar.clearcache() (on page 11-22)
bufferVar.collectchannels (on page 11-23)
bufferVar.collecttimestamps (on page 11-24)
bufferVar.dates (on page 11-25)
bufferVar.formattedreadings (on page 11-26)
bufferVar.fractionalseconds (on page 11-27)
bufferVar.n (on page 11-28)
bufferVar.ptpseconds (on page 11-28)
bufferVar.readings (on page 11-29)
bufferVar.relativetimestamps (on page 11-31)
bufferVar.seconds (on page 11-32)
bufferVar.statuses (on page 11-33)
bufferVar.times (on page 11-34)
bufferVar.timestampresolution (on page 11-35)
bufferVar.timestamps (on page 11-36)
bufferVar.units (on page 11-37)
Reset
Resets settings to their default settings.
digio.trigger[N].reset() (on page 11-121)
lan.reset() (on page 11-265)
localnode.reset() (on page 11-289)
reset() (on page 11-308)
timer.reset() (on page 11-405)
trigger.blender[N].reset() (on page 11-408)
trigger.timer[N].reset() (on page 11-416)
tsplink.trigger[N].reset() (on page 11-429)
Queries and response messages
You can use the print(), printbuffer(), and printnumber() functions to query the
instrument and generate response messages. The format attributes control how the data is formatted
for the print functions used.
The localnode commands determine if generated errors are automatically sent and if prompts are
generated.
format.asciiprecision (on page 11-245)
format.byteorder (on page 11-246)
format.data (on page 11-247)
localnode.prompts (on page 11-288)
localnode.prompts4882 (on page 11-289)
localnode.showerrors (on page 11-291)
print() (on page 11-298)
printbuffer() (on page 11-299)
printnumber() (on page 11-302)

Table of Contents

Other manuals for Keithley 3706A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3706A and is the answer not in the manual?

Keithley 3706A Specifications

General IconGeneral
Model3706A
CategorySystem Switch/Multimeter
Voltage Range100 nV to 300 V
Basic DC Voltage Accuracy0.0035%
Basic Resistance Accuracy0.01%
Maximum Channels576
Maximum Voltage300 V
ConnectivityLAN, USB, GPIB
InterfaceLAN, USB, GPIB
Switching MatrixYes
Channels576 (6-slot mainframe)
Maximum Current3 A