Section 9: Introduction to TSP operation Series 3700A System Switch/Multimeter Reference Manual
9-32 3700AS-901-01 Rev. D/June 2018
Saved setups
Use the saved setups commands to save or restore the configurations to or from the nonvolatile
memory of the instrument or an installed USB flash drive. You can use the setup.poweron attribute
to specify which setup is recalled when the instrument is turned on.
createconfigscript() (on page 11-110)
setup.cards() (on page 11-354)
setup.poweron (on page 11-355)
setup.recall() (on page 11-356)
setup.save() (on page 11-356)
Scan
The scan functions and attributes allow you to set up scanning over the remove interface.
scan.abort() (on page 11-308)
scan.add() (on page 11-309)
scan.addimagestep() (on page 11-311)
scan.addwrite() (on page 11-312)
scan.background() (on page 11-313)
scan.bypass (on page 11-314)
scan.create() (on page 11-315)
scan.execute() (on page 11-317)
scan.list() (on page 11-318)
scan.measurecount (on page 11-320)
scan.mode (on page 11-321)
scan.nobufferbackground() (on page 11-322)
scan.nobufferexecute() (on page 11-323)
scan.reset() (on page 11-324)
scan.scancount (on page 11-325)
scan.state() (on page 11-326)
scan.stepcount (on page 11-327)
scan.trigger.arm.clear() (on page 11-327)
scan.trigger.arm.set() (on page 11-328)
scan.trigger.arm.stimulus (on page 11-328)
scan.trigger.channel.clear() (on page 11-330)
scan.trigger.channel.set() (on page 11-330)
scan.trigger.channel.stimulus (on page 11-331)
scan.trigger.clear() (on page 11-332)
scan.trigger.measure.clear() (on page 11-333)
scan.trigger.measure.set() (on page 11-333)
scan.trigger.measure.stimulus (on page 11-334)
scan.trigger.sequence.clear() (on page 11-335)
scan.trigger.sequence.set() (on page 11-336)
scan.trigger.sequence.stimulus (on page 11-336)

Table of Contents

Other manuals for Keithley 3706A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3706A and is the answer not in the manual?

Keithley 3706A Specifications

General IconGeneral
Model3706A
CategorySystem Switch/Multimeter
Voltage Range100 nV to 300 V
Basic DC Voltage Accuracy0.0035%
Basic Resistance Accuracy0.01%
Maximum Channels576
Maximum Voltage300 V
ConnectivityLAN, USB, GPIB
InterfaceLAN, USB, GPIB
Switching MatrixYes
Channels576 (6-slot mainframe)
Maximum Current3 A