3700AS-901-01 Rev. D/June 2018 11-327
scan.stepcount
This attribute returns the number of steps in the present scan.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Attribute (R)
Yes
Not applicable
Not applicable
Not applicable
Usage
scanStepCount = scan.stepcount
scanStepCount
The present step count value
Details
This is set by the number of steps in the active scan list. The value of this attribute is initially
determined when the scan is created. Adding steps with the scan.create(),
scan.addimagestep(), and scan.add() functions updates this attribute's value.
Example
print(scan.stepcount)
Responds with the present step count.
Output assuming there are five steps in the
scan list:
5.00000e+00
Also see
scan.add() (on page 11-309)
scan.addimagestep() (on page 11-311)
scan.create() (on page 11-315)
Scanning and triggering (on page 5-23)
scan.trigger.arm.clear()
This function clears the arm event detector.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
scan.trigger.arm.clear()
Details
This function sets the trigger model's arm event detector to the undetected state.
Example
scan.trigger.arm.clear()
Clears the arm event detector.
Also see
scan.trigger.arm.set() (on page 11-328)
scan.trigger.arm.stimulus (on page 11-328)
Trigger model (on page 5-24)
Scanning and triggering (on page 5-23)

Table of Contents

Other manuals for Keithley 3706A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3706A and is the answer not in the manual?

Keithley 3706A Specifications

General IconGeneral
Model3706A
CategorySystem Switch/Multimeter
Voltage Range100 nV to 300 V
Basic DC Voltage Accuracy0.0035%
Basic Resistance Accuracy0.01%
Maximum Channels576
Maximum Voltage300 V
ConnectivityLAN, USB, GPIB
InterfaceLAN, USB, GPIB
Switching MatrixYes
Channels576 (6-slot mainframe)
Maximum Current3 A

Related product manuals