X8 MIG WELDER 2.8 Technical data
Warning:
Only an authorized electrician is allowed to carry out electrical work.
Caution:
Before removing the cover plate, disconnect the power source from the mains and wait
for about 2 minutes before discharging the capacitor.
Check the electric connectors of the unit at least every six months. Clean oxidized parts and
tighten loose connectors.
Note:
Use the correct tension torque when fastening loose parts.
Clean the outside parts of the unit from dust and dirt, for example, with a soft brush and vacuum
cleaner. Also clean the ventilation grill at the back of the unit. Do not use compressed air, there is
a risk that the dirt will compact even more tightly into gaps of cooling profiles.
Note:
Do not use pressure washing devices.
Update the wire feeder to the latest firmware version and load new welding software.
2.7.3 Service workshops
Kemppi Service Workshops complete the welding system maintenance according to the Kemppi
service agreement.
The main aspects in the service workshop maintenance procedure are:
• Cleanup of the machine
• Maintenance of the welding tools
• Checkup of the connectors and switches
• Checkup of all electric connections
• Checkup of the power source mains cable and plug
• Repair of defective parts and replacement of defective components
• Maintenance test
• Test and calibration of operation and performance values when needed
Find your closest service workshop at Kemppi website.
2.8 Technical data
This section contains the technical details of the welding system.
2.8.1 X8 Power Source 400 A
Feature Description Value
Mains connection cable H07RN-F 6mm²
Mains connection voltage 3~50/60Hz 380-460V±10%
OPERATING MANUAL | EN 162
©
KEMPPI 2017 | 1817