Page #122 background imageLoading...
Page #122 background image
Note
While in Emergency Mode, the Surveillance function cannot be toggled between enabled and disabled by operating the
transceiver.
Configuration using KPG-D1/ D1N
Configuring Surveillance Mode to be enabled or disabled (
Transceiver Settings > Emergency > Emergency
Information)
2.6
ID Sent When Emergency Mode is Activated
The Emergency ID can be sent each time the transceiver starts automatic transmission and reception in Emergency Mode.
Emergency ID
In a DMR Conventional system, an Emergency ID is the type of code to be sent out each time the transceiver starts
automatic emergency transmission and reception in Emergency Mode.
Table 2-8 Emergency ID (DMR Conventional)
Configuration
Description
None
The transceiver transmits and receives according to the configuration for Color Code of the Zone-channel
used for Emergency Mode.
DMR
When transmitting in Emergency Mode, the transceiver initiates a Group Call or an Individual Call according
to the configurations for Emergency DMR ID Type and Emergency DMR ID.
Also, the following status IDs that are sent when automatic transmission in Emergency Mode is started
can be configured for each factor that activates Emergency Mode (Emergency Key, Lone Worker, Man-
down, Stationary, or Motion):
0
Emergency Call Status
The status ID that is sent when the transceiver enters Emergency Mode by pressing the Emergency
key
0
Lone Worker Status
The status ID that is sent when the transceiver enters Emergency Mode by the Lone Worker function
0
Man-down Status
The status ID that is sent when the transceiver enters Emergency Mode by the Man-down function
0
Stationary Status
The status ID that is sent when the transceiver enters Emergency Mode by the Stationary function
0
Motion Status
The status ID that is sent when the transceiver enters Emergency Mode by the Motion function
If the status ID of the corresponding activation factor is not configured and the activation factor places
the transceiver in Emergency Mode, the status ID configured in Emergency Call Status is sent.
Configuration using KPG-D1/ D1N
0
Configuring Emergency
ID (DMR Conventional) (
Transceiver Settings > Personal > Personal Features > DMR
Conventional > Emergency > Emergency ID (DMR Conventional))
0
Configuring various status IDs (
Transceiver Settings > Personal > Personal Features > DMR Conventional >
Emergency > Emergency ID (DMR Conventional))
2 COMMUNICATIONS IN AN EMERGENCY
2.5 Indication and Sound in Emergency Mode
DMR FUNC (K, F)/Ver 2.20 105
CONTENTS INDEX

Table of Contents

Other manuals for Kenwood NX-5200K3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenwood NX-5200K3 and is the answer not in the manual?

Kenwood NX-5200K3 Specifications

General IconGeneral
BrandKenwood
ModelNX-5200K3
CategoryTransceiver
LanguageEnglish

Related product manuals