110 Keysight Agile Signal Generator Service Guide
Assembly Replacement
7. Refer to Figure 3-15. Remove the power supply by pulling up on the
attached handle.
Figure 3-15 A2 Power Supply Removal
Replacement Procedure
1. Reverse the order of the removal procedure.
2. Recommended torque for all screws is 9 in–lbs.
3. Perform the post-repair performance tests that pertain to this
replacement procedure, see Chapter 4, “Post-Repair Procedures and
Operational Performance Verification.”.
Ensure the power supply is seated properly and the connector pins are not bent.