Application Programs 6
Keysight 34420A User’s Guide 245
RS-232 Operations with QuickBASIC
This program example uses QuickBASIC and the 82335B GPIB Interface Card and
command library for IBM® PC compatibles.
CLS
LOCATE 1, 1
DIM cmd$(100), resp$(1000)
’ Set up serial port for 9600 baud, even parity, 7 bits;
’ Ignore Request to Send Carrier Detect; Send line feed;
’ enable parity check, reserve 1000 bytes for input buffer
OPEN "com1:9600,e,7,2,rs,cd,lf,pe" FOR RANDOM AS #1 LEN = 1000
’ Put the meter into remote operation mode
PRINT #1, "SYST:REM"
’ Query the meter’s id string
’ PRINT #1, "*IDN?"
LINE INPUT #1, resp$
PRINT "*IDN? returned: ", resp$
’ Get the SCPI revision number
PRINT #1, "SYST:VERS?"
LINE INPUT #1, resp$
PRINT "SYST:VERS returned: ", resp$
’ Send a message to the meter’s display
PRINT #1, "DISP:TEXT ’Keysight 34420A’ "
’ Configure the meter for dc voltage measurements, 10 V range,
’ 0.1 V resolution, take 4 readings
PRINT #1, "CONF:VOLT:DC 10, 0.1, ;:SAMP:COUN 4"
’ Trigger the readings and get the results
PRINT #1, "READ?"

Table of Contents