Command Summary
Keysight 3458A Quick Reference Guide 35
Keysight 3458A Quick Reference Guide 35
NRDGS [count][,event]
Number of Readings. Designates the number of
readings taken per trigger and the event (sample
event) that initiates each reading.
count: Designates the number of readings per
trigger event. The valid range for this parameter is
1 to 16777215 (The count parameter also
corresponds to the record parameter in the RMEM
command.)
Power-on count = 1.
Default count = 1.
event = AUTO (1), EXT (2), SYN (5), TIMER (6),
LEVEL (7), LINE (8)
Power-on event = AUTO.
Default event = AUTO.
OCOMP [control]
The OCOMP command enables or disables the
offset compensated ohms function.
control = OFF (0), ON (1)
Power-on control = OFF.
Default control = ON.
OFORMAT [format]
Output Format. Designates the GPIB output
format for readings sent directly to the controller
or transferred from reading memory to the
controller.
format = ASCII (1), SINT (2), DINT (3), SREAL (4),
DREAL (5)