Loading...
3 Spectrum Analyzer Mode
3.6 Power Stat CCDF Measurement
n Results Returned
# Item Unit, if
any
8 Power level that has 0.0001% of the power
9 Peak power dB
10 Count
11 Power level that has 0.00001% of the power if "Minimum Probability" on
page 1138 is PP7 (0.00001 %)
This value is returned only when PP7 is selected
2 Returns a series of 5001 floating point numbers (in percent) that represent the current measured power
stat trace. This is the probability at particular power levels (average power), in the following order:
1. Probability at 0.0 dB power
2. Probability at 0.01 dB power
3. Probability at 0.02 dB power
5000. Probability at 49.9 dB power
5001. Probability at 50.0 dB power
3 Returns a series of 5001 floating point numbers (in percent) that represent the Gaussian trace. This is the
probability at particular power levels (average power), in the following order:
1. Probability at 0.0 dB power
2. Probability at 0.01 dB power
3. Probability at 0.02 dB power
5000. Probability at 49.9 dB power
5001. Probability at 50.0 dB power
4 Returns a series of 5001 floating point numbers (in percent) that represent the user-definable reference
trace. This is the probability at particular power levels (average power), in the following order:
1. Probability at 0.0 dB power
2. Probability at 0.01 dB power
3. Probability at 0.02 dB power
5000. Probability at 49.9 dB power
5001. Probability at 50.0 dB power
3.6.1 Views
In the LTEATDD and 5GNR Modes, this measurement has two views: "Normal" on
page 1134 and Slot. In all other Modes, there is only a single view (Normal).
Spectrum Analyzer Mode User's &Programmer's Reference 1133