EasyManua.ls Logo

Keysight N9041B - Averaging On;Off; Average Mode

Keysight N9041B
2852 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Spectrum Analyzer Mode
3.8 Spurious Emissions Measurement
Remote
Command
[:SENSe]:SPURious:AVERage:COUNt <integer>
[:SENSe]:SPURious:AVERage:COUNt?
Example
:SPUR:AVER:COUN 2500
:SPUR:AVER:COUN?
Preset 10
State Saved Saved in instrument state
Min/Max 1/10000
Averaging On/Off
Turns Averaging on or off.
NOTE
In this measurement, the Average Type is preset to the Log-Pwr Avg (Video)
method. Other averaging methods are not available.
Remote Command
[:SENSe]:SPURious:AVERage[:STATe] ON | OFF | 1 | 0
[:SENSe]:SPURious:AVERage[:STATe]?
Example
:SPUR:AVER ON
:SPUR:AVER?
Preset
OFF
State Saved Saved in instrument state
Range
ON|OFF
Average Mode
Lets you set the Averaging Mode. Options are:
EXPonential: The measurement averaging continues using the specified
number of averages to compute each averaged value. The average will be
displayed at the end of each sweep
REPeat: The measurement resets the average counter each time the specified
number of averages is reached
Remote
Command
[:SENSe]:SPURious:AVERage:TCONtrol EXPonential | REPeat
[:SENSe]:SPURious:AVERage:TCONtrol?
Example
:SPUR:AVER:TCON REP
:SPUR:AVER:TCON?
Preset
EXPonential
1432 Spectrum Analyzer Mode User's &Programmer's Reference