AC current measurement
AC current measurement can be performed by using an AC current clamp.
Keysight recommends the U1583B AC current clamp.
To measure AC current:
1 Connect the AC current clamp to channel 1 or channel 2.
2 Press / to access the connected channel submenu.
3 Press to access the probe setup submenu.
4 Toggle to set the unit to Amps.
5 Press repeatedly to select the required V/A range for the AC
current clamp.
Invert control
This control inverts the displayed waveform with respect to the ground level.
Invert affects how a channel is displayed, but does not affect triggering. Inverting
a channel also changes the result of any function selected in the Analyzer
Controls menu.
To invert a channel waveform:
1 Press to access the invert and bandwidth limit control submenu.
2 Toggle .