84
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
Thousand’place of LED:
Reserved
A8.01
Fault masking
selection 1
Unit’s place of LED:
Communication fault masking
selection
Ten’s place of LED:
Relay faultmasking selection
Hundred’s place of LED:
EEPROMfault masking selection
Thousand’s place of LED:
Reserved
0:Disable.Stop when fault
happen
1:Disable.Continue operating
when fault happen
2:Enable
1
0000
×
0~2222H
A8.02
Fault masking
selection 2
Unit’s place of LED:
Open phase fault masking
selection for input
Ten’s place of LED:
Open phase fault masking
selection for output
0:Disable.Stop when fault happen
1:Disable.Continue operating
when fault happen
2:Enable
1
00
×
0~22H
A8.03
Motor overload
protection mode
selection
0: Disabled
1:Common mode (with low speed
compensation)
2: Variable frequency motor
(without low speed
compensation)
1
1
×
0~2
A8.04
Auto reset times
0No function
1~100Auto reset times
Note: The IGBT protection
(E010) and external equipment
fault (E015) cannot be reset
1
0
×
0~100