86
Function
code
Name
Descriptions
Unit
Factory
setting
Modif.
Setting
range
protection
coefficient
b0.13
Oscillation
inhibition
coefficient
0~255
1
10
0~255
Group b1:V/F parameters
b1.00
V/F curve setting
0V/F curve is defined by user
12-order curve
21.7-order curve
31.2-order curve
1
0
×
0~3
b1.01
V/F frequency
value F3
B1.03~A0.08
0.01Hz
0.00Hz
×
0~30000
b1.02
V/F voltage value
V3
B1.04~100.0%
0.1%
0.0%
×
0~1000
b1.03
V/F frequency
value F2
B1.05 ~B1.01
0.01Hz
0.00Hz
×
0~30000
b1.04
V/F voltage value
V2
B1.06~B1.02
0.1%
0.0%
×
0~1000
b1.05
V/F frequency
value F1
0.00~B1.03
0.01Hz
0.00Hz
×
0~30000
b1.06
V/F voltage value
V1
0~B1.04
0.1%
0.0%
×
0~1000
b1.07
Cut-off point used
for manual torque
boost
0.0%~50.0%( Corresonding to
A0.12)
0.1%
10.0%
0~500
b1.08
AVR function
0Disable
1Enable all the time
2Disabled in Dec process
1
2
×
0~2
Group b2:Enhanced parameters
b2.00
Carrier wave
frequency
2.0~15.0KHz
0.1
8.0
20~150
b2.01
Auto adjusting of
CWF
0Disable
1Enable
1
1
0~1
b2.02
Voltage adjustment
selection
Unit’s place of LED:
Over-voltage at stall Selection
0:Disable(When install brake
1
001
×
0~111H