5-5
See Page 4-23 for access and removal pro-
cedures for the ambient thermostat.
Touch the leads of an ohmmeter to the two
terminals of the ambient thermostat.
The meter should indicate continuity when the
temperature is above ________ degrees
F.
1.
2.
3.
AMBIENT THERMOSTAT
(UW, BC)
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
See page 4-11 for access and removal pro-
cedures for the defrost bimetal.
Touch the leads of an ohmmeter to the two
terminals of the defrost bimetal.
The bimetal opens at 4 degrees C, 40 de-
grees F. and closes as -4 degrees C, 25 de-
grees F.
1.
2.
3.
DEFROST BIMETAL