Section 10
Specifications
20425644
5-2005/Rev 0
10-6
10.4 Electrical Specifications
Electrical System
Motor type TEFC (Totally Enclosed Fan Cooled)
Ampacity and Power Voltage Requirements
Power Voltage
Motor
Horsepower
Full Load
Amps
Recommended
Circuit Breaker
Amps
208/3/50-60 30 86 125
230/3/60 30 76 100
400/3/50 30 43 60
415/3/50 30 43 60
460/3/60 30 38 50
575/3/60 30 32 40
10.5 Hydraulic and High Pressure Water System Specifications
Hydraulic System
Maximum operating pressure 3,000 psi (207 bar)
Main system relief valve 3,400 psi (234 bar)