Section 3
Maintenance
20425569
5-2005/Rev 0
3-3
Many components are lubricated prior to assembly. Table 3-1 lists the recommended lubricants
and their applications. Substitutions are not recommended.
Table 3-1
Lubrication Specifications
Description Application Part Number
Pure Goop Stainless steel threads 10084440
FML-2 Grease O-rings, backup rings, bearing rings, seal
components
10087385
JL-M Grease Non-stainless steel threads 49832199
3.3 Maintenance Precautions
Make sure all safety devices are operational. Each device should be checked on a specified
schedule. If the device does not function, it must be replaced before operating the machine.
Before performing any maintenance on the equipment, take the system out of service and make
sure the controls are properly locked and marked. Never perform any maintenance on the
equipment without making sure the main control power is locked out in the
OFF position.
• Never service or maintain the equipment while it is operating.
• All high pressure leaks must be repaired immediately. Turn the control power off and
bleed off the high pressure water from the intensifier before performing maintenance.
• Never service or maintain any high pressure component, or loosen any high pressure
fitting when it is pressurized. Turn the control power off and bleed off the high pressure
water from the intensifier before servicing.
• If leakage occurs at a sealing surface, high pressure water is released through weep holes.
If a pressurized fitting is loosened, a jet of high pressure water will exit the nearest weep
hole with possible hazardous results.