SECTION 8
ELECTRICAL SYSTEM
p. 8-8
05148408
After pressing the Start button:
The motor starter in the control panel is activated and the motor
starts.
The intensifier assembly starts operating. Reversal position is sensed
by proximity switches, which send signals to the PLC inside the
control panel. The PLC activates the opposite solenoid on the pump
reversing valve.