EasyManuals Logo

KMT STREAMLINE SL-IV 50 PLUS User Manual

KMT STREAMLINE SL-IV 50 PLUS
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
SECTION 11
SPECIFICATIONS
p. 11-6
49836240
11.3 Cutting Water Specifications
The cutting water supply to the waterjet pump must meet the following
specifications. High concentration of dissolved solids, especially calcium, silica,
and chlorides, will affect high pressure component life. A water analysis will
indicate the type of water treatment necessary.
Water Quality Parameters
Minimum
Requirement
Better Best
Alkalinity (mg/l) 50 25 10
Calcium (mg/l) 25 5 0.5
Carbon Dioxide (mg/l) 0 0 0
Chloride as Cl (mg/l) 15 1 0.1
Free Chlorine (mg/l) 0.05 0.05 0.05
Iron as Fe (mg/l) 0.2 0.1 0.01
Magnesium as Mg (mg/l) 0.5 0.1 0.1
Manganese as Mn (mg/l) 0.1 0.1 0.1
Nitrate (mg/l) 25 25 10
Oxygen (mg/l) 2 1 0.1
pH Value 6.5 - 8.5 6.5 - 8.5 6.5 - 8.5
Silica (mg/l) 15 10 1
Sodium (mg/l) 50 10 1
Sulfate (mg/l) 25 25 1
Total Dissolved Solids (mg/l) 200 100 5*
Total Hardness as CaCO3
(mg/l)
25 15 1
Turbidity (NTU) 5 5 1
* Do not reduce beyond this amount or the water will become too aggressive.
11.4 Cooling Water Specifications
Depending on the type of cooling system (closed recirculation, once through,
etc.), the following common problems can be experienced:
Closed recirculation:
Corrosion
Fouling
Once through:
Corrosion
Fouling
Scale
Microbiological
Scale control is the most common problem, and is the result of insoluble matter
deposited on the heat transfer surface. Calcium carbonate is the primary cause of
scale when calcium bicarbonate breaks down. As the temperature of the water
increases it becomes less able to hold carbonates in suspension.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KMT STREAMLINE SL-IV 50 PLUS and is the answer not in the manual?

KMT STREAMLINE SL-IV 50 PLUS Specifications

General IconGeneral
BrandKMT
ModelSTREAMLINE SL-IV 50 PLUS
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals