SECTION 3
OPERATION
p. 3-12
05146410
SET-UP SCREEN (2)
This screen will be displayed if analog control present.
Select if Proportional Pressure
, Pressure Transducer, or both are in unit.
PSI/BAR selector button changes pressure display on RUN screen and
PRESSURE CONTROL screen
There are two SET-UP SCREENS – If analog pressure control is not
installed on the machine, a screen will appear that does not include the
TRANSDUCER and PROPORTIONAL SELECT buttons. These buttons
are used only if a pressure transducer and/or a proportional valve are
installed on the machine
WATER RESET FUNCTION Press on (I) to shut water off five (5) minutes
after machine shuts down. Selecting this
function will insure that the inlet cutting
water is shut off following a shutdown fault.
This can prevent water from leaking past a
damaged water seal following an overstroke
shutdown caused by a seal failure.
IDLE SHUTDOWN TIMER
To set idle shutdown time press up/down
arrows from 5-30 minute increments. This
feature saves energy by automatically shutting
down the intensifier if it is not being used.
Redundant-press on (I) if two topworks are
present. This function changes screens to
indicate two topworks are present.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KMT STREAMLINE SL-IV 50 PLUS and is the answer not in the manual?

KMT STREAMLINE SL-IV 50 PLUS Specifications

General IconGeneral
BrandKMT
ModelSTREAMLINE SL-IV 50 PLUS
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals