SECTION 7
HIGH PRESSURE WATER
p. 7-2
80078868
7.2 Intensifier Disassembly and Reassembly
Detailed instructions are provided on disassembly and reassembly of the
hydraulic intensifier, including HP seal maintenance. A discussion of detailed
inspection and repair for individual HP components and subassemblies is also
provided. The HP attenuator is discussed but no disassembly procedures are
included. Note that HP attenuators are not considered to be serviceable by
the customer.
Some special terms used in this section include:
1. HSEC: - Hard Seal End Cap – (Items 7, 10 and 12 Figure 7-2)
2. HP Cylinder Jug: High Pressure Cylinder, Sealing Head Assembly and
End Cap assembly treated as a unit. – (Items 1, 3, 7, etc. Figure 7-2)
3. Hydraulic Cylinder: Hydraulic Cylinder Body, Hydraulic Cylinder Heads
(2 each), and Hydraulic Piston. – (Items 15, 4, 21, etc. Figure 7-2)
4. Jackbolt – (Item 10, Figure 7-2)