EasyManuals Logo

KMT STREAMLINE SL-IV 50 PLUS User Manual

KMT STREAMLINE SL-IV 50 PLUS
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
SECTION 10
RECIRCULATION SYSTEM
Page 10-3
49836026
10.2 Operation
The recirculation pump (1) takes oil from the tank (8) and pumps it to the oil to
water heat exchanger (3), then to the oil filter (5) and back to the tank.
The visual indicator (4) indicates when the filter element needs replacement. It
should be read when both the water jet pump is running and the oil
temperature is approximately 115°F.
Oil fill port must be used when pumping oil into tank to assure cleanliness. By
filling at this point, the hydraulic oil must pass through the hydraulic filter to
get to the hydraulic tank, guaranteeing that the oil into the tank gets passed
through a filter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KMT STREAMLINE SL-IV 50 PLUS and is the answer not in the manual?

KMT STREAMLINE SL-IV 50 PLUS Specifications

General IconGeneral
BrandKMT
ModelSTREAMLINE SL-IV 50 PLUS
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals