SECTION 3
OPERATION
p. 3-3
05146410
(3) Machine equipped with HP transducer-start up after E-stop:
same as (1) above.
(4) Machine equipped with HP transducer-start up after normal
stop: If pressure is allowed to bleed through orifice to below
1,000 psi, dump valve will open and start up will be like (1)
above, if pressure is not allowed to bleed, start up will be as (2)
above.
The display screen will always default to the Run screen after being
on any other screen more than 5 minutes.
If the intensifier is equipped with a HP transducer, the displayed
pressure can be shown in psi or Bar. Recalibration of the transducer
is automatic and does not require operator input.
If the intensifier is equipped with an hp transducer, another level of
overstroke protection is obtained by shutting down at the warning
level if the pressure is less than 3,000 psi.
The display saves the last 100 alarm shutdown messages, which can
be viewed with times, dates and message contents.