66 A-61837 September 2016
Replacing the imaging
guides
The imaging guides should be replaced when they are heavily scratched and
defects show in the image.
1. Power down the scanner.
2. Open the scanner cover.
3. Loosen the screws on each end of the lower imaging guide and remove it
from its position.
NOTE: Handle the imaging guides carefully so as to not put fingerprints
on the guides.
4. Install the new imaging guide and tighten the screws to secure the imaging
guide.
5. Repeat Steps 3 and 4 to replace the upper imaging guide.
6. Close the scanner cover.
Replacing the Flippable
White Background strip(s)
In the rare case that you may need to replace the Flippable White Background
strip(s), follow the procedures below.
1. Power down the scanner.
2. Open the scanner cover.
3. Loosen the two screws on each end of the lower background strip and
remove it from its position.
4. Disconnect the background strip connector.
5. Connect the new background strip connector with the cable. Be sure it is
securely in place.
6. Install the new background strip and tighten both screws on each side to
secure the background strip.
7. Repeat Steps 3 - 6 to replace the upper background strip.
8. Close the scanner cover.