E03012 2/02 Statex III Electrical Checkout Procedure E3-3
9. If one or more events have been stored, a screen as shown in either Figure 3-2 or 3-3 will be
displayed.
10. If Figure 3-2 is displayed, select “reset hardware startup event” with the cursor and press
[ENTER].
a. A screen will appear with instructions for cycling control power to reset the system. Follow
the on-screen instructions to cycle power to the control system.
b. After the system is powered up, repeat steps 4 through 8 to return to the event data.
11. If Figure 3-3 is displayed, you may select “VIEW EVENT DATA” and press [ENTER] to view
events currently stored. A screen displaying a list of stored events appears.
12. Any stored events may be uploaded to a file for storage by selecting “GE engineering format
event data” and following directions on the subsequent screens.
13. To erase the event data currently stored, select erase event data yes/no menu” from the
EVENT DATA MENU screen.
a. On the screen titled RESET ALL YES/NO MENU, move the cursor to YES, Erase Truck
Events and press [ENTER].
b. Exit back to the GE STATEX III MENU following screen instructions as they appear.
PTUSTX: 1.2.1 EVENT DATA MENU
Special Operation
5 Events stored
( ) VIEW EVENT DATA
Event Summary and Details
( ) reset hardware startup event
( ) GE engineering format event data
( ) EXIT
FIGURE 3-2. EVENT DATA MENU
(Requires Control System Reset)
PTUSTX: 1.2.1 EVENT DATA MENU
Special Operation
5 Events stored
( ) VIEW EVENT DATA
Event Summary and Details
( ) erase event data yes/no menu
( ) GE engineering format event data
( ) EXIT
FIGURE 3-3. EVENT DATA MENU