Envelopes
72
When the threshold is positive (or 0), the envelope resets when passing through the threshold moving upwards. In
other words, if the value has been below the Threshold, and then changes so that it is equal to or greater than the
Threshold, the envelope resets.
When the threshold is negative, the envelope resets when passing through the threshold moving downwards. In other
words, if the value has been above the Threshold, and then changes so that it is equal to or below than the Threshold,
the envelope resets.
Note: modulation sources may not always reliably reach the extreme values of +100 or -100. This can happen due to
smoothing, or with LFOs when using certain shapes and faster speeds. If this is the case, Thresholds of +100 or -100
will cause inconsistent behavior. To avoid this issue, reduce the Threshold until the Envelope resets consistently.
Trigger at Note-On
[Off, On]
Trigger at Note-On is available for the Filter, Osc 1, and Osc 2 Envelopes. The Amp Envelope always triggers at note-
on.
On: The envelope will start automatically at note-on. This is the default.
Off: The envelope will only start via the Trigger Source.
Note: The Trigger Source’s value at note-on can cause the envelope to trigger instantly. If the Threshold is positive or
0, this will happen if the value is at or above the Threshold; if the Threshold is negative, this will happen if the value is
at or below the Threshold.