6.6 Switching the charging station on and off
Switch the following component on to turn it on or off to turn it off:
1. 1F1 Circuit breaker
Wait until the charging station has started
up (approx. 3 minutes).
After the charging station has booted up,
the readiness for operation is displayed on
the HMI.
If necessary, open the Operator menu and
make the desired settings.
(OCPP, grid connection, etc.).
6.6.1 Earth fault/insulation monitoring
The charging station is equipped with an insulation
monitoring system that monitors the insulation of
the charging cable and charge controller before
and during the charging process. If this message
appears before or during the charging process, the
charging process is stopped immediately.
Insulation fault before switching on the car's battery contactors
If an insulation fault occurs before the car's battery contactors are switched on, the charging process in
progress is aborted. An error message is displayed on the control panel. A message is sent to the service.
The charging output is permanently shut down and can only be reactivated by service or operator
personnel.
Fig 11: Earth fault/insulation monitoring
1F1
Fig 10: 1F1 Circuit breaker