BA 348-01 * 2.0 * 34801b510.fm 5-3
Maintenance 5
5.2 Fuel system
Specific safety instructions regarding refuelling
Extreme caution is essential when handling fuel – high risk of fire!
Never perform work on the fuel system near open flames or sparks!
Do not smoke when working on the fuel system or when refuelling!
Before refuelling, stop the engine and remove the ignition key!
Do not refuel in closed rooms!
Wipe away fuel spills immediately!
Keep the machine clean to reduce the risk of fire!
Diesel fuel specification
Caution!
Use only the diesel fuels listed in the table below!
If other fuels are used, warranty rights shall not apply in case of diesel
engine damage (guarantee)!
Do not use diesel fuel with additives
Refuelling
The filler inlet of the fuel tank is located on the left-hand side of the machine in front of the
access
Danger!
Fire and vapour inhalation hazard!
In order to avoid intoxication and fire hazards, do not refuel in enclosed areas!
Never perform work on the fuel system near open flames or sparks
Environment!
Use a suitable container to collect the fuel as it drains and dispose of it in an
environmentally friendly manner!
Specification Cetane number Use (°C)
DIN EN 590 (EU)
ASTM D975-94 (USA)
Min. 49 Up to -44 °C outside temperature
EN 14214 (biodiesel)
Min. 51
Up to 20 °C outside temperature
Fig. 162 : Fuel filler inlet