BA 348-01 * 2.0 * 34801b510.fm 5-9
Maintenance 5
Checking the coolant level/filling up coolant
Notice!
Check the coolant level every 10 operating hours or once a day.
Check before starting the engine.
Checking the coolant level
Park the machine on level ground
Stop the engine and remove the ignition key
Apply the parking brake with the switch on the instrument panel
Open the engine cover
Check the coolant level in the transparent coolant reservoir B
If the coolant level is below seam LOW of the reservoir:
Add coolant
Adding coolant
Danger!
The cooling system is hot and under high pressure!
Never open the coolant reservoir or drain coolant if the engine is hot!
Wait at least 10 minutes after stopping the engine!
Wear protective gloves and clothing
Open filler cap A to the first notch and release the pressure
Open filler cap A fully
Add coolant up to the lower edge of the filler inlet (radiator)
Coolant –seeFluids and lubricants on page 5-39
Close filler cap A
Start the engine and let it warm up for about 5 -– 10 minutes.
Stop the engine and check the coolant level again
The coolant level must be between the LOW and FULL reservoir seams
If necessary, add coolant and repeat the procedure until the coolant level remains constant
Fig. 168 : Coolant reservoir