Loading...
3-26 BA 348-01 * 2.0 * 34801b330.fm
3 Operation
3.17 Key-based drive interlock (option)
Key-based drive interlock: scope of delivery
The drive interlock is integrated in the ignition lock and can be enabled only with the blue
ignition keys!
Scope of delivery:
Drive interlock installed in the machine
2 x blue keys (coded)
1 x red master key (for coding a blue key)
Coding (“training”) new ignition keys
New personal keys are coded with the master key (red). This is why it must be carefully
stored outside the machine.
Notice!
Important!
The new key (blue) cannot be coded unless the machine lights
(side marker lights) are switched on.
Switch on the machine lights see chapter 3 “Machine lights (option)” on
page 3-57
Caution!
Each drive interlock has only one master key!
The drive interlock must be replaced by an authorized service centre if the
master key is lost.
The master key is only used for coding new keys, and cannot be used for disabling the
drive interlock
Coding is performed by inserting the master key in the ignition lock and by turning it to
position 1 for a maximum 5 seconds. After the master key has been returned to position
0 and removed, you have 15 seconds for inserting a key that requires coding. It must
be inserted in the ignition lock and turned to position 1 in order to be registered as a
valid key
Coding is automatically stopped if no key requiring coding is detected within 15 seconds
Several keys requiring coding can be inserted one after another in the ignition lock
Each key must remain at least 1 second in position 1
Coding can be performed for a maximum 10 keys

Table of Contents