10. - Maintenance and storage
KN021BGB K
Mower conditioner
Coupling device b:
To depressurize the circuit
- Place the machine in working position.
- Shift the tractor's hydraulic valve in float position.
- Open valve.
- Release pressure until the gauge needle reads
0 bar (0 psi).
- Shut-off valve.
-
(b): For machines with serial number as from
B0266.
The hydro-pneumatic accumulator does not require
any particular maintenance.
- Regularly check the tightness of the accumulator
fixing bolts and that no oil has leaked from the
hydraulic circuit (a small oil leak can change
settings).
Pressurize the hydraulic circuit before
activating any other hydraulic function of the
machine.
In France, hydro-pneumatic accumulators
must be checked for pressure every 10 years
by an authorized organization: The DRIRE
(Direction régionale de l'Industrie, de la
Recherche et de l'Environnement) for
example.