FC313RF
78
10. - Maintenance and storage
KN021BGB K
Mower conditioner
10.4.3 Checking the roller parallelism and gap
Stop (1) located on each side of the conditioner are
factory set to ensure the parallelism and minimum
roller gap.
- Readjust if necessary.
Screw (1) and counter-nut (2) are coated with
Loctite 243 when fitted.
Check minimum gap between rollers:
J = 2 to 3 mm (0.08’’ - 0.12’’).
Block screw and counter-nut.
The use of Loctite 243 is recommended.