Regular tasks
Fuels
From local standards to the EN14961
The quality requirements for pellets were adhered to, in Germany in the DIN 51731, in Austria
in the ÖNORM M 7135 and in Switzerland in the standard SN 166000.
With the certificate "DIN-Plus
", the DIN 51731 and ÖNORM M7135 were unified and supple-
mented by requirements for abrasion resistance and testing procedure.
The "EN14961" replaces the respective national regulations: The corresponding "ENplus" certifi-
cate simplifies the difficulty consumers have when selecting but it also regulates the professio-
nal handling of the pellets by the trade: Gentle transport, optimal filling of the pellet storage
container ...
The pellets for your KWB heating system must comply with one of the following standards:
ÖNORM M 7135 or DIN 51731 (standardised quality requirements) or
"ENplus"certificate according to standard EN 14961-2 (www.enplus-pellets.de)
SN 166000
Inferior fuels lead to increased emissions and to sintering of the boiler. Only high-quality pellets
ensure a reliable and clean operation of your system and low operating costs. Observe the cor-
responding certificate of your supply company.
Filling / refilling with fuel
If the system is not filled in due time, the Alarm 08 – The fuel storage bunker is empty!
Please refill! [ 54] appears and the system switches off.
WARNING
Toxic gases
m
Toxic gases can enter the storage room as a result of the negative pressure
during the filling process! This could lead to serious personal injury or death.
4
Please ensure that when maintenance and repair work is being carried out
the entire heating system has been shut down with the help of the main
switch!
4
Switching the system off (System on/off [ 22])
4
Seal the openings of the storage room so they are dust-tight
The spring arms of the stirrer must NOT be retracted during the filling of the
storage room.
See also
2
System on/off [ 22]
2
Alarm 08 – The fuel storage bunker is empty! Please refill! [ 54]
5
5.1
5.1.1
EN14961
Intended fuels
5.1.2
Regular tasks
5
B KWB Easyfire EN, 05.2011
19

Table of Contents

Other manuals for KWB Easyfire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KWB Easyfire and is the answer not in the manual?

KWB Easyfire Specifications

General IconGeneral
Fuel TypeWood pellets
Cleaning SystemAutomatic heat exchanger cleaning
Emission Class5
Nominal Heat Output10 kW
TypePellet heating system
Ash RemovalAutomatic
Heating capacity10 kW
Hopper capacity15 kg
Flue diameter130 mm

Related product manuals