Maintenance
WARNING
Perform work according to the instructions for operation only! Improper work
can put you in life-threatening situations:
m
Danger of crushing and entanglement through unexpected starting of mech-
anisms
m
Fire, explosion and electric shock risk from open cladding, combustion
chamber door and service cover
m
Asphyxiation risk due to carbonisation gases from smoldering fuel when the
combustion chamber door or service cover is open!
4
Shut the system down (Menu "System ON/OFF").
4
Switch the system off (main switch to "0").
4
Pull the plug and secure the system against being switched on again.
4
Allow the system to cool down. Only open the cladding, combustion cham-
ber door and service cover when the system is cold and de-energised!
Standards for maintenance
The subsequent regulations originate from the Austrian "Technischen Richtlinie für vorbeugen-
den Brandschutz" [TRVB H118] (Technical Guideline for Preventative Fire Protection) – ensure
that you comply with all corresponding local regulations!
Weekly visual inspection
Perform a weekly inspection of the entire system including the
fuel storage room. Immediately
remedy any deficiencies that are found!
Monthly inspections
Cleanliness of the flue-gas routes (flue-gas passes in the boiler, adapter and chimney)
Proper operation of the control … Are alarm messages displayed?
Functionality of fault alarms and warning device(s);
Proper operation of the combustion air fan and induced draught fan … Are alarm messag-
es displayed?
Proper condition of the combustion chamber … Are alarm messages displayed?
In addition also provide for:
a fire extinguisher that is ready for use and can be carried,
a boiler room free of flammable materials,
fully functional fire protection closures (fire protection closures – self-closing),
legible system stickers, which KWB has provided for safe and correct operation (please
order new stickers if necessary)
Additional regular work
m
Your KWB Easyfire is equipped with an automatic cleaning system. All ash is collected in
the ash container.
4
Empty the
ash container regularly.
7
7.1
7.1.1
7.1.2
7.1.3
7
Maintenance
42
B KWB Easyfire EN, 05.2011

Table of Contents

Other manuals for KWB Easyfire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KWB Easyfire and is the answer not in the manual?

KWB Easyfire Specifications

General IconGeneral
Fuel TypeWood pellets
Cleaning SystemAutomatic heat exchanger cleaning
Emission Class5
Nominal Heat Output10 kW
TypePellet heating system
Ash RemovalAutomatic
Heating capacity10 kW