Room temperature
Main menu >> Room temperature >> Heating circuit No.
Input of the desired temperatures
Actual temperature:
Displays the measured value of the heating circuit room sensor
.
Comment: Is only displayed when an actual room sensor is connected!
Please note: A correction of the room temperature by ±5 °C on the analogue remote con-
trol unit changes the value displayed here in the opposite direction!
Example: If you set the control on the analogue remote control unit to +5 °C, the value in
Actual temperature will fall from 18 °C to 13 °C. As a consequence the heating sys-
tem will heat more powerfully.
Day temp.:
Input of target room temperature during the day
Night temp.:
Input target room temperature during night lowering (specified in the heating program [
24])
Party operation
Main menu >> Party mode >> Heating circuit No.
Enter the time up until the selected heating circuit is to be supplied with heat. After this, the
system runs normally again (normally the night lowering usually follows).
Deactivate the function by entering "00:00".
Heating circuits
Every "heating circuit
" is a self-contained water circuit in a heating system: A pump transports
the hot water to the radiators ("forward flow") where the heat is transferred from the water to
the radiator; the water, now cooled down, then flows back to the boiler ("return flow") where it
is heated up again.
6.3
6.4
6.5
The commands of the KWB Comfort 3 control
6
Room temperature
B KWB Easyfire EN, 05.2011
23

Table of Contents

Other manuals for KWB Easyfire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KWB Easyfire and is the answer not in the manual?

KWB Easyfire Specifications

General IconGeneral
Fuel TypeWood pellets
Cleaning SystemAutomatic heat exchanger cleaning
Emission Class5
Nominal Heat Output10 kW
TypePellet heating system
Ash RemovalAutomatic
Heating capacity10 kW
Hopper capacity15 kg
Flue diameter130 mm