Heating
times
From To From To From To
Wednesday 6:00 8:00 18:00 20:00 20:00 20:00
Thursday 6:00 8:00 18:00 20:00 20:00 20:00
Friday 6:00 8:00 18:00 20:00 20:00 20:00
Saturday 6:00 8:00 18:00 20:00 20:00 20:00
Sunday 6:00 8:00 18:00 20:00 20:00 20:00
Holiday program
Main menu >> Heating circuits >> Heating circuit No. >> Hol-
iday program
Start
The "Frost protection
" mode is activated on this day.
End
The set heating program is reactivated on this day. During the holiday time, the room tempera-
ture is held at approximately 8 °C (factory setting).
Boiler
A "boiler
" ("DHWC") is the storage container for hot water.
DHWC program
Main menu >> Boiler >> Boiler No. >> Boiler program
The header shows the current boiler program.
4
Select how the DHWC will essentially be "charged" (= heated up):
Time program
If the minimum temperature is fallen below during the stored charging times, the hot water
storage tank contents is heated up to the maximum temperature.
Tip: This program is primarily suited for DHWCs that are additionally heated via solar power.
Temperature
Independently of the charging time, the DHWC is always heated up to the maximum tempera-
ture if the minimum temperature was undershot.
6.5.3
6.6
6.6.1
6