Maximum
The contents are heated up up to this temperature.
Actual temperature
Measured domestic hot water temperature
.
Minimum
The domestic hot water temperature may drop to this temperature, it is then heated up.
Holiday program
Main menu >> Boiler >> Boiler No. >> Holiday program
Start:
The DHWC is switched off on this day
.
End:
The DHWC is switched on on this day and the set boiler program is activated.
Fast charging
Main menu >> Boiler >> Boiler No. >> Fast charging
This will immediately heat up the contents of the DHWC – independently from the current boil-
er program
.
Fast charging:
If set to On, the system starts charging the DHWC. After successful heating up, up to the max-
imum temperature, the status of the system automatically switches off again Off. The heat-
ing of the DHWC then occurs depending on the set boiler program.
Buffer
A "buffer" ("buffer tank") is an intermediate storage tank for heat which the boiler generates
during short operating times in the optimal power range.
Buffer program
Main menu >> Boiler >> Boiler No. >> Buffer program
6.6.4
6.6.5
6.7
6.7.1
6
The commands of the KWB Comfort 3 control
Buffer
28
B KWB Easyfire EN, 05.2011