8.1.2 Displaying the alarm statistics 51
8.2 The alarm list 52
8.2.1 Alarm 00 – The control system is not completely adjusted 52
8.2.2 Alarm 01 – The memory module is faulty 52
8.2.3 Alarm 02 – Electronic defect on the digital inputs 52
8.2.4 Alarm 03 – The time must be reset 52
8.2.5 Alarm 04 – The maintenance interval has elapsed. Notify customer serv-
ice.
52
8.2.6 Alarm 05 – Safety thermostat! Boiler overheating! 53
8.2.7 Alarm 06 – Main drive motor is overheated! 53
8.2.8 Alarm 07 – The ignition does not function! 53
8.2.9 Alarm 08 – The fuel storage bunker is empty! Please refill! 54
8.2.10 Alarm 09 – Flue-gas sensor values not plausible! 54
8.2.11 Alarm 10 – The return flow boost does not function! 54
8.2.12 Alarm 12 – Flue-gas temperature too low during operation 55
8.2.13 Alarm 13 – Temperature increase in the fuel supply, fire alarm! 55
8.2.14 Alarm 14 – The electronics have a temperature of 70 °C! 55
8.2.15 Alarm 15 – The flue-gas sensor is missing or is defective! 55
8.2.16 Alarm 16 – The flue-gas sensor cable is missing or is defective! 55
8.2.17 Alarm 17 – The boiler sensor is missing or is defective! 56
8.2.18 Alarm 19 –The ash container is not installed correctly! 56
8.2.19 Alarm 21 – Configuration error! The configuration last saved is active! 56
8.2.20 Alarm 22 – Flue-gas temperature too high during operation 56
8.2.21 Alarm 23 – The fuel storage container is empty! 56
8.2.22 Alarm 24 – Error on the sample probes system 57
8.2.23 Alarm 25 – Main drive speed too low! 57
8.2.24 Alarm 26 – Main drive speed too high 57
8.2.25 Alarm 27 – Boiler temperature not plausible! 57
8.2.26 Alarm 30 –The forward flow sensor of heating circuit 0 is missing or defec-
tive!
57
8.2.27 Alarm 31 – The room sensor of heating circuit 0 is missing or defective! 57
8.2.28 Alarm 32 –The outdoor sensor of heating circuit 0 is missing or defective! 57
8.2.29 Alarms 33 to 134 58
8.2.30 Alarms 135 to 151 – The sensor from the boiler x is missing or defective! 58
8.2.31 Alarms 152 to 185 – The sensor 1 (2) from the buffer x is missing or de-
fective!
58
8.2.32 Alarm 187 – Network error on the boiler module 2! 58
8.2.33 Alarms 188 to 203 – Network error on the heating circuit module x! 58
Table of Contents (Index)
B KWB Easyfire EN, 05.2011
5

Table of Contents

Other manuals for KWB Easyfire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KWB Easyfire and is the answer not in the manual?

KWB Easyfire Specifications

General IconGeneral
Fuel TypeWood pellets
Cleaning SystemAutomatic heat exchanger cleaning
Emission Class5
Nominal Heat Output10 kW
TypePellet heating system
Ash RemovalAutomatic
Heating capacity10 kW
Hopper capacity15 kg
Flue diameter130 mm

Related product manuals