3-1-39
2A3/4
7. Detach the SRDF connector.
8. Remove the seven screws holding the rear cover and then the cover.
9. Route the dehumidifier relay cable using the five wire saddles.
10. Insert 2-pin connector of the drawer heater into the 2-pin connector of the
dehumidifier relay cable.
11. Insert the 2-pin connector of the main harness into the 2-pin connector of the
dehumidifier relay cable.
12. Insert the 4-pin connector of the main harness into the 4-pin connector of the
dehumidifier relay cable.
2-pin connector
Dehumidifier relay cable
4-pin connector
4-pin connector
2-pin connector
2-pin connector
Main harness
Wire saddle
1-pin connectors
Wire saddle
Wire saddle
Wire saddle
Wire saddle
Connector
Main harness
Drawer heater cable
Figure 3-1-48