2A3/4
3-3-64
3-3-9 Fixing section
( 1 ) Detaching and refitting fixing heaters M and S
Replace fixing heaters M and S as follows.
<Procedure>
1. While raising the fixing unit release lever, draw the fixing unit out of the machine.
2. Remove the screw holding the fixing unit and then the unit.
Screw
Fixing unit
Fixing unit release lever
*Illustration shows a 42 ppm.
Figure 3-3-75 Detaching the fixing unit