2A3/4
3-3-39
(10) Adjusting the scanner leading edge registration
Perform the following adjustment if there is regular error between the leading edges of
the copy image and original.
U034
(P.3-3-18)
U404
(P.3-3-100)
U066
U071
(P.3-3-98)
U403
(P.3-3-40)
U 402
(P.3-3-20)
Caution: Before making the following adjustment, ensure that the above adjustments
have been made in maintenance mode.
<Procedure>
Is the scanner
leading edge registration
correct?
Yes
No
Start
Enter maintenance mode.
Enter "066" using the numeric keys.
Press the print key.
Press the interrupt key.
Set an A3 size original and
make a test copy with
the 100% magnification.
For copy sample 1, decrease
the value using the Down key.
For copy sample 2, increase
the value using the Up keys.
Press the print key.
The new setting
is stored.
Press the stop/clear key.
Exit maintenance mode.
Setting range: –32.0 - +32.0
Changing the value by 1 moves
the leading edge by 0.17 mm.
Reference: 0
End
Figure 3-3-47
Original Copy
sample 1
Copy