EasyManua.ls Logo

Kyocera KM-4230

Kyocera KM-4230
602 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2A3/4
3-6-89
Problem Causes Check procedures/corrective measures
Check for continuity across the coil. If none,
replace the switchback feedshift solenoid.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, remedy or replace the cable.
Check if the switchback feedshift solenoid
operates when CN5-B8 on the DF driver
PCB is low. If it does, replace the DF driver
PCB.
Check for continuity across the coil. If none,
replace the eject feedshift solenoid.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, remedy or replace the cable.
Check if the eject feedshift solenoid
operates when CN5-A7 on the DF driver
PCB is low. If it does, replace the DF driver
PCB.
Check for continuity across the coil. If none,
replace the switchback pressure solenoid.
Reinsert the connector. Also check for
continuity within the connector cable. If
none, remedy or replace the cable.
Check if the switchback pressure solenoid
operates when CN5-A2 or CN5-A3 on the
DF driver PCB is low. If it does, replace the
DF driver PCB.
(4)
The switch-
back feedshift
solenoid does
not operate.
(5)
The eject
feedshift sole-
noid does not
operate.
(6)
The switch-
back pressure
solenoid does
not operate.
Defective switch-
back feedshift so-
lenoid coil.
The connector
terminals of the
switchback feed-
shift solenoid
make poor contact.
Defective DF
driver PCB.
Defective eject
feedshift solenoid
coil.
The connector
terminals of the
eject feedshift
solenoid make
poor contact.
Defective DF
driver PCB.
Defective switch-
back pressure so-
lenoid coil.
The connector
terminals of the
switchback pres-
sure solenoid
make poor contact.
Defective DF
driver PCB.

Table of Contents