2FB/2FC-4
1-5-47
C9060 DP EEPROM error
• Read and write data does not match.
• Data in the specified area of the
backup memory does not match the
specified values.
Defective DP main
PWB.
Replace the DP main PWB and check for
correct operation.
Device damage of
EEPROM.
Contact the Service Administrative Division.
C9070 Communication problem between DP
and SHD
• A communication error is detected.
Loose connection
of the SHD PWB.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Defective SHD
PWB.
Replace the SHD PWB and check for cor-
rect operation.
Defective DP main
PWB.
Replace the DP main PWB and check for
correct operation.
C9080 Communication problem between DP
and CIS
Loose connection
of CIS.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Defective CIS. Replace CIS and check for correct opera-
tion.
Code Contents
Remarks
Causes Check procedures/corrective measures
1-5-45-2