2FB/2FC
1-6-73
(4) Detaching and refitting the cleaning felt
Follow the procedure below to replace the cleaning felt.
Procedure
1. Remove the fuser unit (see page 1-6-70).
2. Remove rear pin and front screw, and then
remove the upper fuser cover.
Figure 1-6-140
3. Remove four screws and then remove the
upper fuser frame.
Figure 1-6-141
4. Remove the screw and then remove the
fuser cleaning cover from the upper fuser
frame.
Figure 1-6-142
Upper fuser cover
Pin
Screw
Fuser unit
Upper fuser frame
Fuser unit
Fuser cleaning cover
Upper fuser frame

Table of Contents