2FB/2FC
1-5-53
(10)Image is blurred. Causes
1. Scanner moves erratically.
2. Deformed press roller.
3. Paper conveying section drive problem.
Causes Check procedures/corrective measures
1. Scanner moves erratically.
Check if there is any foreign matter on the front and rear scanner rails. If
any, remove it.
2. Deformed press roller.
Replace the press roller (see page 1-6-72).
3. Paper conveying section drive problem.
Check the gears and belts and, if necessary, grease them.
(11)The leading edge of the image is
consistently misaligned with the
original.
Causes
1. Misadjusted leading edge registration.
2. Misadjusted scanner leading edge registration.
3. Registration motor operating incorrectly.
4. Misadjusted the amount of slack in the paper.
Causes Check procedures/corrective measures
1. Misadjusted leading edge registration.
Readjust the leading edge registration (see page 1-6-25).
2. Misadjusted scanner leading edge regis-
tration.
Readjust the scanner leading edge registration (see page 1-6-54).
3. Registration motor operating incorrectly.
Check the installation of the registration motor. If it operates incorrectly,
replace it.
4. Misadjusted the amount of slack in the
paper.
Run maintenance item U051 to readjust the amount of slack in the paper.
(12)The leading edge of the image is
sporadically misaligned with the
original.
Causes
1. Registration motor, MP feed motor, paper feed motor 1, paper feed motor 2,
paper feed motor 3 or paper feed motor 4 installed or operating incorrectly.
Causes Check procedures/corrective measures
1. Registration motor, MP feed motor, paper
feed motor 1, paper feed motor 2, paper
feed motor 3 or paper feed motor 4
installed or operating incorrectly.
Check the installation position and operation of the registration motor, MP
feed motor, paper feed motor 1, paper feed motor 2, paper feed motor 3
and paper feed motor 4. If any of them operates incorrectly, replace it.