2L6/2N6/2N5/2N4
1-4-130
6610 Fuser release sensor error
The fusing pressure release 
nal in 5 seconds since a pres-
sure release instruction is 
given for the fusing pressure 
motor.
The fusing pressure release 
nal in 5 seconds since a pres-
sure instruction is given for 
the fusing pressure motor.
.
Fuser release 
motor
1. To check the motor operation, execute 
U030 Fuser Release (see page 1-3-34).
2. Check that the drive gear can be rotated  
and the separation is possible.
 
wiring connector is firmly connected 
and, if necessary, connect the connector 
all the way in.
Fuser unit and Engine PWB (YC26)
4. If the wiring is disconnected, shorted or 
grounded, replace the wiring.
5. Replace the fuser unit and execute 
U167 counter clear (see page 1-3-112). 
Fuser release 
sensor
1. Check that the sensor is correctly 
positioned.
2. Check that the sensor is not 
contaminated or damaged.
Engine PWB 1. Check the engine software and upgrade 
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).
6710 Fuser IH PWB CPU reset 
error
Watch doc timer has been 
overflowed.
Fuser IH PWB
1. Confirm that the wiring connector is 
firmly connected and, if necessary, 
connect the connector all the way in.
Fuser IH PWB( YC4) and Engine PWB 
(YC26)
2. If the wiring is disconnected, shorted or 
grounded, replace the wiring.
3. Replace the fuser IH PWB (see page 1-
5-96).
Engine PWB 1. Check the engine software and upgrade 
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).