8100 DF eject release motor error
When the DF eject release
motor is driven, DF bundle
discharge sensor does not
turn on within 1 s.
DF eject release
motor
DF bundle
discharge unit
sensor
1. Execute Motor - Eject Unlock (Full) of
U240 finisher operation check (see page
1-3-134).
2. Check that the eject guide of the
process tray is opened and, if not, cor-
rect the guide.
3. Check that the drive from the motor
reaches the eject guide.
4. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF bundle discharge unit sensor and DF
main PWB (YC22)(4000-sheet finisher)
DF bundle discharge unit sensor and DF
main PWB (YC20)(1000-sheet finisher)
5. If the wiring is disconnected, shorted or
grounded, replace the wiring.
6. Replace the DF eject release motor.
DF bundle
discharge unit
sensor
1. Execute Finisher - Bundle Eject HP of
U241 finisher switch check (see page 1-
3-136).
2. Check that the sensor and its mounting
board are correctly positioned.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
DF bundle discharge unit sensor and DF
main PWB (YC22)(4000-sheet finisher)
DF bundle discharge unit sensor and DF
main PWB (YC20)(1000-sheet finisher)
4. Replace the DF bundle discharge unit
sensor.
DF main PWB Replace the DF main PWB (Refer to the
service manual for the document finisher).
Code Contents Related parts
Check procedures/