2L6/2N6/2N5/2N4
1-4-227
2. DP-scanning first (front) page
3. DP-scanning second (back) page (with a dual scan DP installed)
Defective part Check description Corrective Action
1
Original document Check whether the original
document is dirty.
If the original document is dirty, replace.
2
Contact glass Check whether the contact glass
is dirty.
If the contact glass is dirty, clean the contact
glass, and the bottom part of the shading plate.
3
FFC cable CCD Check the FFC cable between
the CCD sensor and ISC PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
4
FFC cable LED Check the FFC cable between
the LED PWB and ISC PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
5
SATA cable ISC
Check the SATA cable between
the ISC PWB and main PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
6
LED PWB Check that the LED is lit. If the LED is not lit, replace the LED PWB and
perform U411.
7
ISC PWB The ISC PWB is defective. Replace the ISC PWB and perform U411.
(see page 1-3-173)
8
Main PWB The main PWB is defective. Replace the main PWB.(see page 1-5-72)
Defective part Check description Corrective Action
1
Original document Check whether the original
document is dirty.
If the original document is dirty, replace.
2
DP_CIS glass Check whether the CIS glass of
the DP is contaminated.
If the CIS glass of the DP is contaminated,
clean. Or, if it has scuffs, replace.
3
DP_CIS unit Check the location the CIS unit
is mounted.
Re-mount the CIS unit if it is hanged off.
4
DP_SHD PWB Check the CIS and the SHD
PWB is properly connected.
Reinsert the connector if the PWB was loosely
inserted.If not cured, replace the PWB.
5
DP_SATA cable Check the FFC cable between
the SHD PWB and ISC PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
6
DP_CIS CIS is defective. Replace the CIS and perform U091 and U411.
(see page 1-3-71,1-3-173)

Table of Contents