4.13.1 - SKIP TO THE NEXT INGREDIENT/UNLOAD
This Function allows the Skip to the Next Ingredient/Unload to be set in
either the Automatic or Manual Mode; the setting will be valid for all the
Ingredients/Unloads of all Recipes. Later, it will be possible in the Recipe
Programming Activity to modify the mode of every single Ingredient/Unload
of every Recipe.
By choosing the Automatic Mode, in the Recipe Execution Activity at the end
of the Queue Time, the equipment will automatically position itself on the
Ingredient/Unload which follows the one appearing on the display.
By choosing the Manual mode, at the end of the Queue Time, the equipment
will continue to display the weight that refers to the loaded or unloaded
Ingredient/Unload. To select the next Ingredient/Unload, press the q key.
To select the preceding Ingredient/Unload, press the z key.
The Manual mode is generally preferable when it is necessary to check the
loaded or unloaded weight of the Ingredients/Unload with great precision.
The Manual mode setting is signalled on the display with the lighting up of
the m symbol.
1. Select the [
JUMP
] Function and confirm by pressing the OK key.
Either the [
AUT.
] or [
MAN.
] message will appear on the display,
depending on the selected setting.
2. Select the desired mode by pressing the q z keys.
[
AUT.
] Automatic Mode, [
MAN.
] Manual Mode.
3. Confirm by pressing the OK key. During the update, the flashing [
WAIT
]
message will appear on the display. According to the max. number of
Recipes set (code 54), the equipment takes max. 2 minutes to complete
the operation.
4. To exit without changing the setting, press the Menu key. The equipment
will return to the Special Function Menu. The [
JUMP
] message will
appear on the display.
5. To exit press the Menu key.
• In the Recipe Programming Activity and the Recipe Execution Activity, the
Manual mode setting is signalled on the display with the lighting up of the
m symbol.
chApter 4 51